Table of Contents Table of Contents
Previous Page  5 / 6 Next Page
Information
Show Menu
Previous Page 5 / 6 Next Page
Page Background

Kulkoni, Inc.

UW v1610

WARNING: NEVER EXCEED WORKING LOAD LIMIT

Page 4

Read important warnings and information on pages 2-9 and page 33 of Kulkoni

general catalog v214.

DOMESTIC CARBON STEEL SWAGING SLEEVES

Dimensions in Inches

Weight Each

in Pounds

Rope

Diameter

in Inches

A

B

C

D

E

Wall

Thickness

After Swage

Diameter

1/4

1.0

0.21/32

0.21/64

0.15/32

0.9/32

3/32

0.50

0.08

5/16

1.1/2

0.29/32

0.7/16

0.39/64

0.7/16

9/64

0.73

0.09

3/8

1.1/2

0.29/32

0.15/32

0.21/32

0.7/16

1/8

0.73

0.12

7/16

2.0

1.7/32

0.9/16

0.27/32

0.19/32

3/16

0.98

0.30

1/2

2.0

1.7/32

0.5/8

0.29/32

0.19/32

5/32

0.98

0.29

9/16

2.3/4

1.15/32

0.11/16

1.1/32

0.45/64

7/32

1.20

0.43

5/8

2.3/4

1.15/32

0.3/4

1.3/32

0.45/64

3/16

1.20

0.57

3/4

3.3/16

1.23/32

0.59/64

1.9/32

0.55/64

7/32

1.41

0.88

7/8

3.9/16

2.1/32

1.1/32

1.17/32

1.0

1/4

1.63

1.36

1

4.0

2.9/32

1.5/32

1.23/32

1.1/8

9/32

1.88

1.95

1.1/8

4.13/16

2.1/2

1.9/32

1.15/16

1.1/4

9/32

2.08

2.60

1.1/4

5.13/64

2.25/32

1.7/16

2.5/32

1.13/32

5/16

2.27

3.40

1.3/8

5.13/16

3.0

1.9/16

2.3/8

1.9/16

5/16

2.46

4.30

1.1/2

6.1/4

3.1/4

1.11/16

2.5/8

1.11/16

5/16

2.65

5.00

1.3/4

7.1/4

3.27/32

1.15/16

3.1/8

1.31/32

23/64

3.04

8.10

2

8.1/2

4.3/8

2.1/4

3.5/8

2.1/4

3/8

3.50

11.25

2.5

10.1/2

5.1/2

2.3/4

4.1/2

2.13/16

1/2

4.44

23.20

3

12.0

6.0

3.1/4

5.0

3.3/8

1/2

4.89

29.40

Recommended for flemished eyes only.

Caution:

When attaching swage sleeves to wire rope it is extremely important to follow recommended procedures.

Flemish Eye Carbon Steel Sleeves are recommended for use on 6 x 19 or 6 x 37 IPS or XIP, EIP, RRL, FC, or IWRC

wire rope. Proper swaging practices are the sling manufacturer's responsibility. A color change will not indicate proper

swaging. Before using sleeves with other type lay, construction, or grade of wire rope, it is recommended that the termi-

nation be proof loaded to prove the adequacy of the assembly.

UPSON-WALTON™ STEEL SWAGING SLEEVES

CAUTION:

Proper swaging practices are the sling manufacturers responsibility. A color change will

not indicate proper swaging.

Upson-Walton™ Flemish Eye Carbon Steel Sleeves