Kulkoni, Inc.
UW v1610
WARNING: NEVER EXCEED WORKING LOAD LIMIT
Page 2
UPSON-WALTON™ OPEN SWAGE SOCKETS
Read important warnings and information on pages 2-9, and page 33 of Kulkoni
general catalog v214.
DOMESTIC OPEN SWAGE SOCKETS
Rope
Diameter
in Inches
Dimensions in Inches
Approx.
Weight Each
in Pounds
A/S*
MIN—MAX
A
B
D
E
F
H
L
M
O
Y
1/4
0.50 0.27 0.69 1.50 4.75 2.13 4.00 0.31 0.69 1.38
0.55
0.428 - 0.460
5/16
0.77 0.34 0.81 1.75 6.25 3.19 5.31 0.41 0.81 1.63
1.10
0.678 - 0.710
3/8
0.77 0.41 0.81 1.75 6.25 3.19 5.31 0.41 0.81 1.63
1.08
0.678 - 0.710
7/16
0.98 0.48 1.00 2.00 7.81 4.25 6.69 0.50 1.00 2.00
2.30
0.865 - 0.910
1/2
0.98 0.55 1.00 2.00 7.81 4.25 6.69 0.50 1.00 2.00
2.25
0.865 - 0.910
9/16
1.26 0.61 1.19 2.25 9.56 5.31 8.13 0.63 1.25 2.50
4.60
1.115 - 1.160
5/8
1.26 0.67 1.19 2.25 9.56 5.31 8.13 0.63 1.25 2.50
4.50
1.115 - 1.160
3/4
1.55 0.80 1.38 2.75 11.69 6.38 10.00 0.75 1.50 3.00
7.80
1.365 - 1.420
7/8
1.70 0.94 1.63 3.25 13.63 7.44 11.63 0.94 1.75 3.38
11.70
1.490 - 1.550
1
1.98 1.06 2.00 3.75 15.63 8.50 13.38 1.03 2.00 4.00
17.80
1.740 - 1.800
1.1/8
2.25 1.19 2.25 4.25 17.50 9.56 15.00 1.19 2.25 4.50
29.70
1.990 - 2.050
1.1/4
2.53 1.33 2.50 4.75 19.44 10.63 16.50 1.19 2.50 5.00
36.00
2.240 - 2.300
1.3/8
2.80 1.45 2.50 5.25 21.25 11.69 18.13 1.31 2.50 5.25
47.00
2.490 - 2.560
1.1/2
3.08 1.58 2.75 5.75 23.25 12.75 19.75 1.44 3.00 5.75
65.00
2.740 - 2.810
1.3/4
3.39 1.86 3.50 6.75 27.13 14.88 23.00 1.69 3.50 7.00
93.00
2.990 - 3.060
2
3.94 2.11 3.75 8.00 31.44 17.00 26.75 1.81 4.00 8.00
145.00
3.490 - 3.560
* A/S indicates the proper dimension of A after swaging.
Swage Sockets are recommended for use on 6 x 19 or 6 x 36 IPS or XIP (EIP), XXIP (EEIP), RRL, FC, or IWRC wire
ropes. They are also approved for use on galvanized bridge rope. Before using swage sockets with other type lay, con-
struction or grade of wire rope, it is recommended that the termination be proofloaded to prove the adequacy of the as-
sembly. Spheroidized annealed for cold swaging. Sockets properly applied have an efficiency rating of 100%. This rating
is based on the catalog breaking strength of wire rope.
Caution:
When attaching swage sockets to wire rope it is extremely important to follow recommended procedures.