Kulkoni, Inc. 1-800-231-2357
Page 51 Kulkoni, Inc. v921 WARNING: NEVER EXCEED WORKING LOAD LIMIT GALVANIZED, DROP FORGED Dimensions in Inches Min. # Clips Wire Rope Turn Back in Inches Torque* (ft.lbs.) Weight per 100 (lbs.) Size in Inches C D Thd. G N 3/16 - 1/4 0.40 0.94 3/8-16 1.41 1.44 2 4.00 30 21 5/16 0.47 1.06 3/8-16 1.50 1.54 2 5.00 30 28 3/8 0.51 1.06 7/16-14 1.84 1.78 2 5.25 45 38 7/16 - 1/2 0.59 1.25 1/2-13 2.21 2.15 3 11.00 65 63 9/16 - 5/8 0.72 1.50 5/8-11 2.72 2.57 3 13.50 130 115 3/4 0.86 1.81 3/4-10 2.94 2.67 3 16.00 225 180 7/8 0.97 2.12 3/4-10 3.31 2.86 4 26.00 225 230 1 1.13 2.25 3/4-10 3.72 3.06 5 37.00 225 275 * Based on clean, unlubricated threads. The table above shows the minimum torque required to reach maximum holding power of wire rope clips. Meets the performance requirements of Federal Specification FF-C-450, current revision, Type 3, Class 1. Improper use and installation of forged wire rope clips can result in serious injury or death. Forged wire rope clips are the only type of wire rope clip approved for lifting purposes. For complete installation instructions refer to page 48. DOUBLE K GRIP WIRE ROPE CLIPS Read important warnings and information on pages 2 - 9 and page 48.