Kulkoni, Inc. 1-800-231-2357

Kulkoni, Inc. v921 WARNING: NEVER EXCEED WORKING LOAD LIMIT Page 12 6 x 26 WARRINGTON 6 x 26 WARRINGTON SEALE WITH FIBER CORE SEALE WITH IWRC According to A.S.T.M. A1023/1023M Wire Rope for General Purposes and Federal Specification RR-W-410, current re- vision, as applicable. Meets the performance requirements of API-9A. Preformed, right regular lay. Drawn Galvanized FIBER CORE (EIPS) Diameter in Inches Approx. Weight per Foot in Pounds Breaking Strength in Tons* 1/4 0.105 3.01 3/8 0.236 6.71 7/16 0.320 9.10 1/2 0.420 11.80 9/16 0.530 14.90 5/8 0.660 18.40 3/4 0.950 26.20 7/8 1.290 35.40 Drawn Galvanized IWRC (EIPS)** Diameter in Inches Approx. Weight per Foot in Pounds Breaking Strength in Tons* 3/8 0.26 7.55 7/16 0.35 10.20 1/2 0.46 13.30 9/16 0.59 16.80 5/8 0.72 20.60 3/4 1.04 29.40 7/8 1.42 39.80 1 1.85 51.70 1.1/8 2.34 65.00 1.1/4 2.89 79.90 1.3/8 3.50 96.00 1.1/2 4.16 114.00 1.5/8 4.88 132.00 1.3/4 5.67 153.00 2 7.39 198.00 * Listed for comparison only. Actual operating loads should never exceed the recommended design factor or 20% of catalog Breaking Strength. ** EEIPS available in some sizes and constructions. GALVANIZED WIRE ROPE - 6 x 19 CLASS Read important warnings and information on pages 2 - 9.

RkJQdWJsaXNoZXIy NDQyOTU4